Graphene-polyaniline composite film modified electrode for voltammetric determination of 4-aminophenol
Fan, Yang1; Liu, Jin-Hang1; Yang, Chun-Peng2; Yu, Meng1; Liu, Peng1
2011-10-20
Source PublicationSENSORS AND ACTUATORS B-CHEMICAL
Volume157Issue:2Pages:669-674
Abstract

An electrochemical sensor based on graphene-polyaniline (GR-PANI) nanocomposite for voltammetric determination of 4-aminophenol (4-AP) is presented. The electrochemical behavior of 4-AP at the GR-PANI composite film modified glassy carbon electrode (GCE) was investigated by cyclic voltammetry. 4-AP exhibits enhanced voltammetric response at GR-PANI modified GCE. This electrochemical sensor shows a favorable analytical performance for 4-AP detection with a detection limit of 6.5 x 10(-8) M and high sensitivity of 604.2 mu A mM(-1). Moreover. 4-AP and paracetamol can be detected simultaneously without interference of each other in a large dynamic range. (C) 2011 Elsevier B.V. All rights reserved.

SubtypeArticle
KeywordGraphene Polyaniline Nanocomposite Aminophenol Electrochemical Sensor
WOS HeadingsScience & Technology ; Physical Sciences ; Technology
DOI10.1016/j.snb.2011.05.053
WOS KeywordWALLED CARBON NANOTUBES ; P-AMINOPHENOL ; ELECTROCHEMICAL-BEHAVIOR ; OXIDE ; FABRICATION ; SENSOR ; NANOCOMPOSITE ; PARACETAMOL ; SYSTEMS
Indexed BySCI
Language英语
WOS Research AreaChemistry ; Electrochemistry ; Instruments & Instrumentation
WOS SubjectChemistry, Analytical ; Electrochemistry ; Instruments & Instrumentation
WOS IDWOS:000293161300048
Citation statistics
Cited Times:141[WOS]   [WOS Record]     [Related Records in WOS]
Document Type期刊论文
Identifierhttp://ir.qibebt.ac.cn/handle/337004/6636
Collection公共实验室
Affiliation1.Xinyang Normal Univ, Coll Chem & Chem Engn, Xinyang 464000, Peoples R China
2.Chinese Acad Sci, Qingdao Inst Bioenergy & Bioproc Technol, Qingdao 266101, Peoples R China
Recommended Citation
GB/T 7714
Fan, Yang,Liu, Jin-Hang,Yang, Chun-Peng,et al. Graphene-polyaniline composite film modified electrode for voltammetric determination of 4-aminophenol[J]. SENSORS AND ACTUATORS B-CHEMICAL,2011,157(2):669-674.
APA Fan, Yang,Liu, Jin-Hang,Yang, Chun-Peng,Yu, Meng,&Liu, Peng.(2011).Graphene-polyaniline composite film modified electrode for voltammetric determination of 4-aminophenol.SENSORS AND ACTUATORS B-CHEMICAL,157(2),669-674.
MLA Fan, Yang,et al."Graphene-polyaniline composite film modified electrode for voltammetric determination of 4-aminophenol".SENSORS AND ACTUATORS B-CHEMICAL 157.2(2011):669-674.
Files in This Item: Download All
File Name/Size DocType Version Access License
Graphene–polyaniline(643KB)期刊论文作者接受稿开放获取CC BY-NC-SAView Download
Related Services
Recommend this item
Bookmark
Usage statistics
Export to Endnote
Google Scholar
Similar articles in Google Scholar
[Fan, Yang]'s Articles
[Liu, Jin-Hang]'s Articles
[Yang, Chun-Peng]'s Articles
Baidu academic
Similar articles in Baidu academic
[Fan, Yang]'s Articles
[Liu, Jin-Hang]'s Articles
[Yang, Chun-Peng]'s Articles
Bing Scholar
Similar articles in Bing Scholar
[Fan, Yang]'s Articles
[Liu, Jin-Hang]'s Articles
[Yang, Chun-Peng]'s Articles
Terms of Use
No data!
Social Bookmark/Share
File name: Graphene–polyaniline composite film modified electrode for voltammetric determination of 4-aminophenol.pdf
Format: Adobe PDF
This file does not support browsing at this time
All comments (0)
No comment.
 

Items in the repository are protected by copyright, with all rights reserved, unless otherwise indicated.