QIBEBT-IR  > 公共实验室
Graphene-polyaniline composite film modified electrode for voltammetric determination of 4-aminophenol
Fan, Yang1; Liu, Jin-Hang1; Yang, Chun-Peng2; Yu, Meng1; Liu, Peng1
2011-10-20
发表期刊SENSORS AND ACTUATORS B-CHEMICAL
卷号157期号:2页码:669-674
摘要

An electrochemical sensor based on graphene-polyaniline (GR-PANI) nanocomposite for voltammetric determination of 4-aminophenol (4-AP) is presented. The electrochemical behavior of 4-AP at the GR-PANI composite film modified glassy carbon electrode (GCE) was investigated by cyclic voltammetry. 4-AP exhibits enhanced voltammetric response at GR-PANI modified GCE. This electrochemical sensor shows a favorable analytical performance for 4-AP detection with a detection limit of 6.5 x 10(-8) M and high sensitivity of 604.2 mu A mM(-1). Moreover. 4-AP and paracetamol can be detected simultaneously without interference of each other in a large dynamic range. (C) 2011 Elsevier B.V. All rights reserved.

文章类型Article
关键词Graphene Polyaniline Nanocomposite Aminophenol Electrochemical Sensor
WOS标题词Science & Technology ; Physical Sciences ; Technology
DOI10.1016/j.snb.2011.05.053
关键词[WOS]WALLED CARBON NANOTUBES ; P-AMINOPHENOL ; ELECTROCHEMICAL-BEHAVIOR ; OXIDE ; FABRICATION ; SENSOR ; NANOCOMPOSITE ; PARACETAMOL ; SYSTEMS
收录类别SCI
语种英语
WOS研究方向Chemistry ; Electrochemistry ; Instruments & Instrumentation
WOS类目Chemistry, Analytical ; Electrochemistry ; Instruments & Instrumentation
WOS记录号WOS:000293161300048
引用统计
文献类型期刊论文
条目标识符http://ir.qibebt.ac.cn/handle/337004/6636
专题公共实验室
作者单位1.Xinyang Normal Univ, Coll Chem & Chem Engn, Xinyang 464000, Peoples R China
2.Chinese Acad Sci, Qingdao Inst Bioenergy & Bioproc Technol, Qingdao 266101, Peoples R China
推荐引用方式
GB/T 7714
Fan, Yang,Liu, Jin-Hang,Yang, Chun-Peng,et al. Graphene-polyaniline composite film modified electrode for voltammetric determination of 4-aminophenol[J]. SENSORS AND ACTUATORS B-CHEMICAL,2011,157(2):669-674.
APA Fan, Yang,Liu, Jin-Hang,Yang, Chun-Peng,Yu, Meng,&Liu, Peng.(2011).Graphene-polyaniline composite film modified electrode for voltammetric determination of 4-aminophenol.SENSORS AND ACTUATORS B-CHEMICAL,157(2),669-674.
MLA Fan, Yang,et al."Graphene-polyaniline composite film modified electrode for voltammetric determination of 4-aminophenol".SENSORS AND ACTUATORS B-CHEMICAL 157.2(2011):669-674.
条目包含的文件 下载所有文件
文件名称/大小 文献类型 版本类型 开放类型 使用许可
Graphene–polyaniline(643KB)期刊论文作者接受稿开放获取CC BY-NC-SA浏览 下载
个性服务
推荐该条目
保存到收藏夹
查看访问统计
导出为Endnote文件
谷歌学术
谷歌学术中相似的文章
[Fan, Yang]的文章
[Liu, Jin-Hang]的文章
[Yang, Chun-Peng]的文章
百度学术
百度学术中相似的文章
[Fan, Yang]的文章
[Liu, Jin-Hang]的文章
[Yang, Chun-Peng]的文章
必应学术
必应学术中相似的文章
[Fan, Yang]的文章
[Liu, Jin-Hang]的文章
[Yang, Chun-Peng]的文章
相关权益政策
暂无数据
收藏/分享
文件名: Graphene–polyaniline composite film modified electrode for voltammetric determination of 4-aminophenol.pdf
格式: Adobe PDF
此文件暂不支持浏览
所有评论 (0)
暂无评论
 

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。