Porous gold cluster film prepared from Au@BSA microspheres for electrochemical nonenzymatic glucose sensor
Han, Lei1,2,3; Zhang, Shu1,2,4,5; Han, Lihui4,5; Yang, Da-Peng1,2; Hou, Chuantao1,2; Liu, Aihua1,2,3
2014-08-20
发表期刊ELECTROCHIMICA ACTA
卷号138页码:109-114
摘要To obtain hierarchically porous gold-cluster film as the direct electrochemical sensing interface for nonenzymatic glucose detection, a facile, cost-effective, environmentally friendly and bottom-up approach was developed by calcination of Au@BSA microspheres. The fabricated gold-cluster film was composed of the network structure interconnected with Au particles and the disordered 3D hierarchical pores. Due to large surface area, high electroconductivity and excellent electrocatalysis towards glucose oxidation, the as-prepared sensor showed high current response so that the glucose determination could be carried out at a less positive potential where common interferents (ascorbic acid, acetamidophenol and uric acid) were not oxidized. Importantly, 0.15 M chloride ions (Cl-) had no poisoning effect on the gold-cluster electrode. Meanwhile, the sensor also exhibited a rapid response (5 s), high sensitivity (10.76 mu A mM(-1) cm(-2)), a low limit of detection (1 mu M), a wide and useful linear range (0.01 - 10 mM), good operational stability and storage stability. This work not only demonstrated an excellent direct electrochemical sensing interface for nonenzymatic detection of glucose, but also would extend to other noble metal films and metal oxide films as various electrodes and electrochemical interface. (C) 2014 Elsevier Ltd. All rights reserved.
文章类型Article
关键词Au@bsa Microsphere Hierarchically Porous Gold-cluster Direct Electrochemical Sensing Nonenzymatic Glucose Sensor
WOS标题词Science & Technology ; Physical Sciences
DOI10.1016/j.electacta.2014.06.095
关键词[WOS]BIOSENSORS ; ELECTRODE ; PLATINUM ; NANOPARTICLES ; CHEMISTRY ; OXIDATION ; TEMPLATE ; ARRAYS
收录类别SCI
语种英语
WOS研究方向Electrochemistry
WOS类目Electrochemistry
WOS记录号WOS:000341464000015
引用统计
文献类型期刊论文
条目标识符http://ir.qibebt.ac.cn/handle/337004/6326
专题生物传感技术团队(过去)
作者单位1.Chinese Acad Sci, Lab Biosensing, Qingdao Inst Bioenergy & Bioproc Technol, Qingdao 266101, Peoples R China
2.Chinese Acad Sci, Key Lab Bioenergy, Qingdao 266101, Peoples R China
3.Univ Chinese Acad Sci, Beijing 100049, Peoples R China
4.Ocean Univ China, Minist Educ, Key Lab Marine Chem Theory & Technol, Qingdao 266100, Peoples R China
5.Ocean Univ China, Coll Chem & Chem Engn, Qingdao 266100, Peoples R China
推荐引用方式
GB/T 7714
Han, Lei,Zhang, Shu,Han, Lihui,et al. Porous gold cluster film prepared from Au@BSA microspheres for electrochemical nonenzymatic glucose sensor[J]. ELECTROCHIMICA ACTA,2014,138:109-114.
APA Han, Lei,Zhang, Shu,Han, Lihui,Yang, Da-Peng,Hou, Chuantao,&Liu, Aihua.(2014).Porous gold cluster film prepared from Au@BSA microspheres for electrochemical nonenzymatic glucose sensor.ELECTROCHIMICA ACTA,138,109-114.
MLA Han, Lei,et al."Porous gold cluster film prepared from Au@BSA microspheres for electrochemical nonenzymatic glucose sensor".ELECTROCHIMICA ACTA 138(2014):109-114.
条目包含的文件
条目无相关文件。
个性服务
推荐该条目
保存到收藏夹
查看访问统计
导出为Endnote文件
谷歌学术
谷歌学术中相似的文章
[Han, Lei]的文章
[Zhang, Shu]的文章
[Han, Lihui]的文章
百度学术
百度学术中相似的文章
[Han, Lei]的文章
[Zhang, Shu]的文章
[Han, Lihui]的文章
必应学术
必应学术中相似的文章
[Han, Lei]的文章
[Zhang, Shu]的文章
[Han, Lihui]的文章
相关权益政策
暂无数据
收藏/分享
所有评论 (0)
暂无评论
 

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。