KMS Qingdao Institute of Biomass Energy and Bioprocess Technology ,CAS
Application of enhanced electronegative multimodal chromatography as the primary capture step for immunoglobulin G purification | |
Wang, Yanli1; Chen, Quan2; Xian, Mo2; Nian, Rui2; Xu, Fei1 | |
2018-06-01 | |
发表期刊 | AMB EXPRESS |
ISSN | 2191-0855 |
卷号 | 8 |
摘要 | In recent studies, electronegative multimodal chromatography with Eshmuno HCX was demonstrated to be a highly promising recovery step for direct immunoglobulin G (IgG) capture from undiluted cell culture fluid. In this study, the binding properties of HCX to IgG at different pH/salt combinations were systematically studied, and its purification performance was significantly enhanced by lowering the washing pH and conductivity after high capacity binding of IgG under its optimal conditions. A single polishing step gave an end-product with non-histone host cell protein (nh-HCP) below 1 ppm, DNA less than 1 ppb, which aggregates less than 0.5% and an overall IgG recovery of 86.2%. The whole non-affinity chromatography based two-column-step process supports direct feed loading without buffer adjustment, thus extraordinarily boosting the overall productivity and cost-savings. |
文章类型 | Article |
关键词 | Monoclonal Antibody Electronegative Multimodal Non-affinity Purification Cost-savings |
WOS标题词 | Science & Technology ; Life Sciences & Biomedicine |
DOI | 10.1186/s13568-018-0622-3 |
关键词[WOS] | CATION-EXCHANGE CHROMATOGRAPHY ; HYDROPHOBIC INTERACTION CHROMATOGRAPHY ; PROTEIN-A CHROMATOGRAPHY ; CELL-CULTURE FLUID ; MONOCLONAL-ANTIBODIES ; VOID-EXCLUSION ; CHROMATIN ; PERFORMANCE ; PH ; CLEARANCE |
收录类别 | SCI |
语种 | 英语 |
WOS研究方向 | Biotechnology & Applied Microbiology |
项目资助者 | National Natural Science Foundation of China(21676286) |
WOS类目 | Biotechnology & Applied Microbiology |
WOS记录号 | WOS:000433978500004 |
出版者 | BIOMED CENTRAL LTD |
引用统计 | |
文献类型 | 期刊论文 |
条目标识符 | http://ir.qibebt.ac.cn/handle/337004/11392 |
专题 | 中国科学院青岛生物能源与过程研究所 |
通讯作者 | Nian, Rui; Xu, Fei |
作者单位 | 1.Jilin Univ, Coll Life Sci, Changchun, Jilin, Peoples R China 2.Chinese Acad Sci, Qingdao Inst Bioenergy & Bioproc Technol, CAS Key Lab Biobased Mat, Qingdao, Peoples R China |
推荐引用方式 GB/T 7714 | Wang, Yanli,Chen, Quan,Xian, Mo,et al. Application of enhanced electronegative multimodal chromatography as the primary capture step for immunoglobulin G purification[J]. AMB EXPRESS,2018,8. |
APA | Wang, Yanli,Chen, Quan,Xian, Mo,Nian, Rui,&Xu, Fei.(2018).Application of enhanced electronegative multimodal chromatography as the primary capture step for immunoglobulin G purification.AMB EXPRESS,8. |
MLA | Wang, Yanli,et al."Application of enhanced electronegative multimodal chromatography as the primary capture step for immunoglobulin G purification".AMB EXPRESS 8(2018). |
条目包含的文件 | 条目无相关文件。 |
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。
修改评论